{"product_id":"sm5391-1-5a-50v-general-purpose-rectifier-diode-sma-do-214ac-low-forward-voltage-reliable-power-rectification-hornby","title":"SM5391 1.5A 50V General Purpose Rectifier Diode | SMA \/ DO-214AC | Low Forward Voltage | Reliable Power Rectification HORNBY","description":"\u003cp data-start=\"397\" data-end=\"746\"\u003eThe \u003cstrong data-start=\"401\" data-end=\"411\"\u003eSM5391\u003c\/strong\u003e General Purpose Rectifier Diode is designed for \u003cstrong data-start=\"460\" data-end=\"506\"\u003eefficient and reliable power rectification\u003c\/strong\u003e in various electronic and power supply applications.\u003cbr data-start=\"559\" data-end=\"562\"\u003eWith a \u003cstrong data-start=\"569\" data-end=\"608\"\u003e50V peak repetitive reverse voltage\u003c\/strong\u003e and \u003cstrong data-start=\"613\" data-end=\"645\"\u003e1.5A average forward current\u003c\/strong\u003e, it ensures \u003cstrong data-start=\"658\" data-end=\"680\"\u003estable performance\u003c\/strong\u003e, \u003cstrong data-start=\"682\" data-end=\"700\"\u003elow power loss\u003c\/strong\u003e, and \u003cstrong data-start=\"706\" data-end=\"745\"\u003eexcellent surge handling capability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"748\" data-end=\"958\"\u003eEncapsulated in a \u003cstrong data-start=\"766\" data-end=\"792\"\u003eSMA \/ DO-214AC package\u003c\/strong\u003e, the SM5391 offers \u003cstrong data-start=\"812\" data-end=\"828\"\u003ecompact size\u003c\/strong\u003e, \u003cstrong data-start=\"830\" data-end=\"861\"\u003eexcellent thermal stability\u003c\/strong\u003e, and \u003cstrong data-start=\"867\" data-end=\"891\"\u003elong-term durability\u003c\/strong\u003e, making it ideal for both \u003cstrong data-start=\"918\" data-end=\"957\"\u003econsumer and industrial electronics\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"960\" data-end=\"963\"\u003e\n\u003ch3 data-start=\"965\" data-end=\"994\"\u003e🔧 \u003cstrong data-start=\"972\" data-end=\"994\"\u003eKey Specifications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"996\" data-end=\"1547\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"996\" data-end=\"1025\"\u003e\n\u003ctr data-start=\"996\" data-end=\"1025\"\u003e\n\u003cth data-start=\"996\" data-end=\"1012\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"998\" data-end=\"1011\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1012\" data-end=\"1025\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1014\" data-end=\"1023\"\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1057\" data-end=\"1547\"\u003e\n\u003ctr data-start=\"1057\" data-end=\"1085\"\u003e\n\u003ctd data-start=\"1057\" data-end=\"1075\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1074\"\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1075\" data-end=\"1085\" data-col-size=\"sm\"\u003eSM5391\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1086\" data-end=\"1126\"\u003e\n\u003ctd data-start=\"1086\" data-end=\"1097\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1096\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1097\" data-end=\"1126\" data-col-size=\"sm\"\u003eGeneral Purpose Rectifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1127\" data-end=\"1190\"\u003e\n\u003ctd data-start=\"1127\" data-end=\"1183\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1129\" data-end=\"1182\"\u003ePeak Repetitive Reverse Voltage (V\u0026lt;sub\u0026gt;RRM\u0026lt;\/sub\u0026gt;)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1183\" data-end=\"1190\" data-col-size=\"sm\"\u003e50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1191\" data-end=\"1255\"\u003e\n\u003ctd data-start=\"1191\" data-end=\"1239\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1193\" data-end=\"1238\"\u003eAverage Forward Current (I\u0026lt;sub\u0026gt;O\u0026lt;\/sub\u0026gt;@T)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1239\" data-end=\"1255\" data-col-size=\"sm\"\u003e1.5A @ 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1256\" data-end=\"1319\"\u003e\n\u003ctd data-start=\"1256\" data-end=\"1312\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1258\" data-end=\"1311\"\u003eMax. Peak Forward Surge Current (I\u0026lt;sub\u0026gt;FSM\u0026lt;\/sub\u0026gt;)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1312\" data-end=\"1319\" data-col-size=\"sm\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1320\" data-end=\"1392\"\u003e\n\u003ctd data-start=\"1320\" data-end=\"1377\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1322\" data-end=\"1376\"\u003eForward Voltage Drop (V\u0026lt;sub\u0026gt;F\u0026lt;\/sub\u0026gt;@I\u0026lt;sub\u0026gt;F\u0026lt;\/sub\u0026gt;)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1377\" data-end=\"1392\" data-col-size=\"sm\"\u003e1.1V @ 1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1393\" data-end=\"1460\"\u003e\n\u003ctd data-start=\"1393\" data-end=\"1445\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1395\" data-end=\"1444\"\u003eReverse Current (I\u0026lt;sub\u0026gt;R\u0026lt;\/sub\u0026gt;@V\u0026lt;sub\u0026gt;R\u0026lt;\/sub\u0026gt;)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1445\" data-end=\"1460\" data-col-size=\"sm\"\u003e5.0µA @ 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1461\" data-end=\"1493\"\u003e\n\u003ctd data-start=\"1461\" data-end=\"1475\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1463\" data-end=\"1474\"\u003ePackage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1475\" data-end=\"1493\" data-col-size=\"sm\"\u003eSMA \/ DO-214AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1494\" data-end=\"1547\"\u003e\n\u003ctd data-start=\"1494\" data-end=\"1528\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1496\" data-end=\"1527\"\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1528\" data-end=\"1547\" data-col-size=\"sm\"\u003e-55°C to +150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1549\" data-end=\"1552\"\u003e\n\u003ch3 data-start=\"1554\" data-end=\"1584\"\u003e💡 \u003cstrong data-start=\"1561\" data-end=\"1584\"\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"1586\" data-end=\"1842\"\u003e\n\u003cli data-start=\"1586\" data-end=\"1640\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1640\"\u003eLow forward voltage for efficient power conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1641\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1643\" data-end=\"1696\"\u003eHigh surge current capability for robust protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1740\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1740\"\u003eStable performance at high temperatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1789\"\u003e\n\u003cp data-start=\"1743\" data-end=\"1789\"\u003eCompact surface-mount SMA \/ DO-214AC package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1790\" data-end=\"1842\"\u003e\n\u003cp data-start=\"1792\" data-end=\"1842\"\u003eReliable for continuous rectification operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1844\" data-end=\"1847\"\u003e\n\u003ch3 data-start=\"1849\" data-end=\"1872\"\u003e⚙️ \u003cstrong data-start=\"1856\" data-end=\"1872\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"1874\" data-end=\"2028\"\u003e\n\u003cli data-start=\"1874\" data-end=\"1911\"\u003e\n\u003cp data-start=\"1876\" data-end=\"1911\"\u003ePower supply and adapter circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1912\" data-end=\"1943\"\u003e\n\u003cp data-start=\"1914\" data-end=\"1943\"\u003eAC to DC conversion modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1944\" data-end=\"1979\"\u003e\n\u003cp data-start=\"1946\" data-end=\"1979\"\u003eBattery chargers and converters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1980\" data-end=\"2028\"\u003e\n\u003cp data-start=\"1982\" data-end=\"2028\"\u003eIndustrial and consumer electronic equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HORNBY","offers":[{"title":"Default Title","offer_id":43229183115329,"sku":"H00002398","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/4468\/5633\/files\/SMC_DO214AC-01_4bb2c36f-81be-40c7-af50-5b6841775308.png?v=1767438467","url":"https:\/\/hext.in\/products\/sm5391-1-5a-50v-general-purpose-rectifier-diode-sma-do-214ac-low-forward-voltage-reliable-power-rectification-hornby","provider":"Hext by Regent Electronics","version":"1.0","type":"link"}