{"product_id":"p4ke6-8ca-6-8v-400w-bi-directional-tvs-diode-do-41-ac-signal-line-surge-protector-sep","title":"P4KE6.8CA – 6.8V 400W Bi-Directional TVS Diode | DO-41 | AC \u0026 Signal Line Surge Protector SEP","description":"\u003cp data-start=\"122\" data-end=\"725\"\u003eThe P4KE6.8CA is a 400W bi-directional transient voltage suppressor designed for AC and bidirectional signal line protection. With a symmetrical breakdown range of 6.45–7.14V, it clamps surges in both polarities, making it ideal for protecting interfaces exposed to alternating voltages, inductive switching, and lightning disturbances. The device supports a 5.8V standoff rating, 10.5V clamping, and 39A pulse capability, ensuring strong suppression while maintaining minimal leakage. Its DO-41 package offers rugged through-hole reliability for industrial, telecom, automation, and consumer equipment.\u003c\/p\u003e\n\u003chr data-start=\"727\" data-end=\"730\"\u003e\n\u003ch3 data-start=\"732\" data-end=\"758\"\u003e\u003cstrong data-start=\"736\" data-end=\"758\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"759\" data-end=\"1044\"\u003e\n\u003cli data-start=\"759\" data-end=\"795\"\u003e\n\u003cp data-start=\"761\" data-end=\"795\"\u003e\u003cstrong data-start=\"761\" data-end=\"788\"\u003eVWM (Standoff Voltage):\u003c\/strong\u003e 5.8V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"796\" data-end=\"839\"\u003e\n\u003cp data-start=\"798\" data-end=\"839\"\u003e\u003cstrong data-start=\"798\" data-end=\"826\"\u003eVBR (Breakdown Voltage):\u003c\/strong\u003e 6.45–7.14V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"840\" data-end=\"876\"\u003e\n\u003cp data-start=\"842\" data-end=\"876\"\u003e\u003cstrong data-start=\"842\" data-end=\"868\"\u003eVC (Clamping Voltage):\u003c\/strong\u003e 10.5V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"877\" data-end=\"914\"\u003e\n\u003cp data-start=\"879\" data-end=\"914\"\u003e\u003cstrong data-start=\"879\" data-end=\"908\"\u003eIPP (Peak Pulse Current):\u003c\/strong\u003e 39A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"951\"\u003e\n\u003cp data-start=\"917\" data-end=\"951\"\u003e\u003cstrong data-start=\"917\" data-end=\"944\"\u003ePPP (Peak Pulse Power):\u003c\/strong\u003e 400W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"952\" data-end=\"988\"\u003e\n\u003cp data-start=\"954\" data-end=\"988\"\u003e\u003cstrong data-start=\"954\" data-end=\"979\"\u003eIR (Leakage Current):\u003c\/strong\u003e 1000µA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"989\" data-end=\"1021\"\u003e\n\u003cp data-start=\"991\" data-end=\"1021\"\u003e\u003cstrong data-start=\"991\" data-end=\"1004\"\u003ePolarity:\u003c\/strong\u003e Bi-Directional\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1044\"\u003e\n\u003cp data-start=\"1024\" data-end=\"1044\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1036\"\u003ePackage:\u003c\/strong\u003e DO-41\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1046\" data-end=\"1049\"\u003e\n\u003ch3 data-start=\"1051\" data-end=\"1067\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1067\"\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1068\" data-end=\"1286\"\u003e\n\u003cli data-start=\"1068\" data-end=\"1117\"\u003e\n\u003cp data-start=\"1070\" data-end=\"1117\"\u003eBi-directional protection for AC\/signal lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1118\" data-end=\"1152\"\u003e\n\u003cp data-start=\"1120\" data-end=\"1152\"\u003e400W surge handling capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1153\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1155\" data-end=\"1180\"\u003eFast transient response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1181\" data-end=\"1219\"\u003e\n\u003cp data-start=\"1183\" data-end=\"1219\"\u003eStable low-leakage characteristics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1220\" data-end=\"1248\"\u003e\n\u003cp data-start=\"1222\" data-end=\"1248\"\u003eStrong clamping at 10.5V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1249\" data-end=\"1286\"\u003e\n\u003cp data-start=\"1251\" data-end=\"1286\"\u003eDO-41 through-hole rugged package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1288\" data-end=\"1291\"\u003e\n\u003ch3 data-start=\"1293\" data-end=\"1313\"\u003e\u003cstrong data-start=\"1297\" data-end=\"1313\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1314\" data-end=\"1533\"\u003e\n\u003cli data-start=\"1314\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1316\" data-end=\"1349\"\u003eAC signal line surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1350\" data-end=\"1395\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1395\"\u003eData communication and I\/O port shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1396\" data-end=\"1438\"\u003e\n\u003cp data-start=\"1398\" data-end=\"1438\"\u003eIndustrial control \u0026amp; sensor interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1439\" data-end=\"1483\"\u003e\n\u003cp data-start=\"1441\" data-end=\"1483\"\u003eRelay\/solenoid inductive kick protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1484\" data-end=\"1533\"\u003e\n\u003cp data-start=\"1486\" data-end=\"1533\"\u003eTelecom, consumer, and automation electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SEP","offers":[{"title":"Default Title","offer_id":43228781772865,"sku":"H00001928","price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/4468\/5633\/files\/1-01_3c67da45-23e6-468a-854d-4e3e2bb380c2.png?v=1767421862","url":"https:\/\/hext.in\/products\/p4ke6-8ca-6-8v-400w-bi-directional-tvs-diode-do-41-ac-signal-line-surge-protector-sep","provider":"Hext by Regent Electronics","version":"1.0","type":"link"}