{"product_id":"2r2500sb-8t36-2500v-gas-discharge-tube-gdt-surge-protector-2rs-8t36-package-ruilon","title":"2R2500SB-8T36 2500V Gas Discharge Tube (GDT) Surge Protector – 2RS-8T36 Package | RUILON","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:fb28836d-5024-410d-a6ea-424568166af4-15\" data-testid=\"conversation-turn-32\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"e5734b7d-4a80-41b5-8bdf-6d3cfcaf7e6e\" dir=\"auto\" data-message-model-slug=\"gpt-5-3\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"114\" data-end=\"552\"\u003eThe \u003cstrong data-start=\"141\" data-end=\"183\"\u003e2R2500SB-8T36 Gas Discharge Tube (GDT)\u003c\/strong\u003e from \u003cstrong data-start=\"189\" data-end=\"199\"\u003eRUILON\u003c\/strong\u003e is an ultra high-voltage ceramic surge protection device designed to protect critical electronic systems from extreme transient overvoltage events such as lightning strikes and high-energy switching surges. With a \u003cstrong data-start=\"414\" data-end=\"445\"\u003e2500V DC spark-over voltage\u003c\/strong\u003e, this component is ideal for applications requiring maximum voltage endurance and superior surge immunity.\u003c\/p\u003e\n\u003cp data-start=\"554\" data-end=\"960\"\u003eBuilt using advanced gas discharge technology, the 2R2500SB-8T36 delivers \u003cstrong data-start=\"628\" data-end=\"675\"\u003estable impulse spark-over voltage at 1KV\/µs\u003c\/strong\u003e, along with \u003cstrong data-start=\"688\" data-end=\"718\"\u003ehigh insulation resistance\u003c\/strong\u003e and \u003cstrong data-start=\"723\" data-end=\"751\"\u003elow capacitance at 1 MHz\u003c\/strong\u003e, ensuring minimal signal interference in sensitive circuits. Its ability to withstand \u003cstrong data-start=\"838\" data-end=\"890\"\u003ehigh impulse discharge current (8\/20µs waveform)\u003c\/strong\u003e provides excellent surge absorption capability and long service life.\u003c\/p\u003e\n\u003cp data-start=\"962\" data-end=\"1316\"\u003eCompared to lower voltage GDT variants, the 2500V model offers exceptional resistance to false triggering in ultra high-voltage environments, making it particularly suitable for power infrastructure and heavy-duty industrial applications. The robust \u003cstrong data-start=\"1212\" data-end=\"1232\"\u003e2RS-8T36 package\u003c\/strong\u003e ensures strong mechanical durability and reliable operation under harsh conditions.\u003c\/p\u003e\n\u003cp data-start=\"1318\" data-end=\"1548\"\u003eThis GDT is widely used in \u003cstrong data-start=\"1345\" data-end=\"1496\"\u003epower transmission systems, telecommunications infrastructure, industrial automation, surge protection devices (SPD), and energy management systems\u003c\/strong\u003e, delivering dependable and long-lasting protection.\u003c\/p\u003e\n\u003chr data-start=\"1550\" data-end=\"1553\"\u003e\n\u003cp data-start=\"1555\" data-end=\"1574\"\u003e\u003cstrong data-start=\"1555\" data-end=\"1572\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1575\" data-end=\"1944\"\u003e\n\u003cli data-section-id=\"j3eu5f\" data-start=\"1575\" data-end=\"1640\"\u003e2500V DC spark-over voltage for ultra high-voltage protection\u003c\/li\u003e\n\u003cli data-section-id=\"usz1lm\" data-start=\"1641\" data-end=\"1691\"\u003eStable impulse spark-over performance (1KV\/µs)\u003c\/li\u003e\n\u003cli data-section-id=\"e1lj48\" data-start=\"1692\" data-end=\"1743\"\u003eHigh surge current capability (8\/20µs waveform)\u003c\/li\u003e\n\u003cli data-section-id=\"zfdsl1\" data-start=\"1744\" data-end=\"1797\"\u003eLow capacitance for signal-sensitive applications\u003c\/li\u003e\n\u003cli data-section-id=\"1ar9mdq\" data-start=\"1798\" data-end=\"1844\"\u003eHigh insulation resistance and reliability\u003c\/li\u003e\n\u003cli data-section-id=\"evlzv5\" data-start=\"1845\" data-end=\"1896\"\u003eDurable 2RS-8T36 package for harsh environments\u003c\/li\u003e\n\u003cli data-section-id=\"vqpqhu\" data-start=\"1897\" data-end=\"1944\"\u003eLong service life with high surge endurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1946\" data-end=\"1949\"\u003e\n\u003cp data-start=\"1951\" data-end=\"1970\"\u003e\u003cstrong data-start=\"1951\" data-end=\"1968\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1971\" data-end=\"2264\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"stk6rr\" data-start=\"1971\" data-end=\"2031\"\u003eHigh-voltage power transmission and distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5hv5\" data-start=\"2032\" data-end=\"2084\"\u003eTelecommunications and networking infrastructure\u003c\/li\u003e\n\u003cli data-section-id=\"lvx3t6\" data-start=\"2085\" data-end=\"2130\"\u003eIndustrial automation and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"7vkfio\" data-start=\"2131\" data-end=\"2165\"\u003eSurge protection devices (SPD)\u003c\/li\u003e\n\u003cli data-section-id=\"5x6h5m\" data-start=\"2166\" data-end=\"2215\"\u003eEnergy management and smart grid applications\u003c\/li\u003e\n\u003cli data-section-id=\"1v87tpa\" data-start=\"2216\" data-end=\"2264\" data-is-last-node=\"\"\u003eHeavy-duty industrial and electronic equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\n\u003cdiv class=\"text-center\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"RUILON","offers":[{"title":"Default Title","offer_id":43771800027201,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/4468\/5633\/files\/VARISTOR-01.png?v=1756461410","url":"https:\/\/hext.in\/products\/2r2500sb-8t36-2500v-gas-discharge-tube-gdt-surge-protector-2rs-8t36-package-ruilon","provider":"Hext by Regent Electronics","version":"1.0","type":"link"}