{"product_id":"2r150tb-8t2-150v-gas-discharge-tube-2rt-8t2-package-ruilon","title":"2R150TB-8T2 150V Gas Discharge Tube – 2RT-8T2 Package | RUILON","description":"\u003cp data-start=\"88\" data-end=\"535\"\u003eThe \u003cstrong data-start=\"115\" data-end=\"155\"\u003e2R150TB-8T2 Gas Discharge Tube (GDT)\u003c\/strong\u003e from \u003cstrong data-start=\"161\" data-end=\"171\"\u003eRUILON\u003c\/strong\u003e is a high-reliability ceramic surge protection device designed to protect sensitive electronic circuits from transient overvoltage events such as lightning strikes, switching surges, and electrostatic discharge (ESD). Utilizing advanced gas discharge technology, it ensures ultra-fast response and stable long-term protection in demanding electrical environments.\u003c\/p\u003e\n\u003cp data-start=\"537\" data-end=\"1042\"\u003eWith a \u003cstrong data-start=\"544\" data-end=\"577\"\u003eDC spark-over voltage of 150V\u003c\/strong\u003e, this component is optimized for low-to-medium voltage surge protection applications, offering a balance between sensitivity and operational stability. Compared to lower-voltage variants, it provides improved resistance to nuisance triggering while still ensuring fast activation during surge events. The device supports high \u003cstrong data-start=\"904\" data-end=\"942\"\u003eimpulse discharge current (8\/20µs)\u003c\/strong\u003e and delivers excellent \u003cstrong data-start=\"966\" data-end=\"1009\"\u003eimpulse spark-over performance (1kV\/µs)\u003c\/strong\u003e for effective surge suppression.\u003c\/p\u003e\n\u003cp data-start=\"1044\" data-end=\"1401\"\u003eThe device features \u003cstrong data-start=\"1064\" data-end=\"1092\"\u003elow capacitance at 1 MHz\u003c\/strong\u003e, helping preserve signal integrity in high-speed communication systems, while \u003cstrong data-start=\"1171\" data-end=\"1201\"\u003ehigh insulation resistance\u003c\/strong\u003e reduces leakage current and improves overall efficiency. Stable \u003cstrong data-start=\"1266\" data-end=\"1314\"\u003eglow voltage and arc voltage characteristics\u003c\/strong\u003e ensure consistent operation, strong energy handling capability, and long service life.\u003c\/p\u003e\n\u003cp data-start=\"1403\" data-end=\"1732\"\u003eEncased in a compact \u003cstrong data-start=\"1424\" data-end=\"1443\"\u003e2RT-8T2 package\u003c\/strong\u003e, the 2R150TB-8T2 allows easy integration into space-constrained PCB designs. It is widely used in \u003cstrong data-start=\"1542\" data-end=\"1661\"\u003etelecommunications equipment, power supplies, industrial automation systems, smart meters, and consumer electronics\u003c\/strong\u003e, delivering reliable surge protection and enhanced system reliability.\u003c\/p\u003e\n\u003chr data-start=\"1734\" data-end=\"1737\"\u003e\n\u003cp data-start=\"1739\" data-end=\"1758\"\u003e\u003cstrong data-start=\"1739\" data-end=\"1756\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1759\" data-end=\"2123\"\u003e\n\u003cli data-section-id=\"6x4imv\" data-start=\"1759\" data-end=\"1789\"\u003e150V DC Spark-Over Voltage\u003c\/li\u003e\n\u003cli data-section-id=\"p54ggi\" data-start=\"1790\" data-end=\"1844\"\u003eHigh impulse discharge current capability (8\/20µs)\u003c\/li\u003e\n\u003cli data-section-id=\"dh9aun\" data-start=\"1845\" data-end=\"1894\"\u003eFast response to transient overvoltage events\u003c\/li\u003e\n\u003cli data-section-id=\"k27bm\" data-start=\"1895\" data-end=\"1948\"\u003eLow capacitance for signal integrity preservation\u003c\/li\u003e\n\u003cli data-section-id=\"oj5ydm\" data-start=\"1949\" data-end=\"2004\"\u003eHigh insulation resistance with low leakage current\u003c\/li\u003e\n\u003cli data-section-id=\"s3y341\" data-start=\"2005\" data-end=\"2052\"\u003eStable glow and arc voltage characteristics\u003c\/li\u003e\n\u003cli data-section-id=\"10hmw0c\" data-start=\"2053\" data-end=\"2095\"\u003eLong service life and high reliability\u003c\/li\u003e\n\u003cli data-section-id=\"l1dple\" data-start=\"2096\" data-end=\"2123\"\u003eCompact 2RT-8T2 package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2125\" data-end=\"2128\"\u003e\n\u003cp data-start=\"2130\" data-end=\"2149\"\u003e\u003cstrong data-start=\"2130\" data-end=\"2147\"\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2150\" data-end=\"2408\"\u003e\n\u003cli data-section-id=\"1p9gxbi\" data-start=\"2150\" data-end=\"2203\"\u003eTelecommunications and data communication systems\u003c\/li\u003e\n\u003cli data-section-id=\"wumgt4\" data-start=\"2204\" data-end=\"2241\"\u003ePower supply and adapter circuits\u003c\/li\u003e\n\u003cli data-section-id=\"k7606u\" data-start=\"2242\" data-end=\"2289\"\u003eIndustrial automation and control equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1751ez9\" data-start=\"2290\" data-end=\"2329\"\u003eSmart meters and smart grid systems\u003c\/li\u003e\n\u003cli data-section-id=\"yxopth\" data-start=\"2330\" data-end=\"2370\"\u003eConsumer electronics and IoT devices\u003c\/li\u003e\n\u003cli data-section-id=\"9jjubo\" data-start=\"2371\" data-end=\"2408\"\u003eSecurity and surveillance systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"RUILON","offers":[{"title":"Default Title","offer_id":43768953700417,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0647\/4468\/5633\/files\/VARISTOR-01.png?v=1756461410","url":"https:\/\/hext.in\/products\/2r150tb-8t2-150v-gas-discharge-tube-2rt-8t2-package-ruilon","provider":"Hext by Regent Electronics","version":"1.0","type":"link"}